EVOLVE Manual Pipettes – Set Volumes More Than Ten Times Faster!

   
   
Request more info
 
How to set volumes
Video - EVOLVE Manual Pipettes
 
Rate this product
 
Related Products
GripTips
Electronic pipettes
 


Set volumes fast!
The EVOLVE manual pipette features three adjustable dials to rapidly set volumes. This revolutionary approach reduces repetitive stress injuries and allows users to set volumes in a fraction of the time it takes with a traditional manual pipette.

GripTip pipette tips that will never fall off
EVOLVE pipettes together with INTEGRA’s wide range of GripTips form a perfect pipetting system. GripTips snap into place with minimal tip loading effort, providing a secure connection. GripTips never fall off and are perfectly aligned, ensuring precise touch offs of fluids resulting in superior pipetting performance.

Operational comfort
Two differently sized plunger springs allow users to customize the force needed to depress the plunger to their preference. The controlled plunger spring option allows users to slow the aspiration and dispense speeds resulting in improved pipetting technique and results. The controlled plunger spring is compatible with all single channel EVOLVE pipettes except the 5 ml model. Changing the spring is completed in seconds. The ultra lightweight, well balanced design of the pipettes provides unsurpassed ergonomics even during prolonged pipetting sessions.

EVOLVE Single Channel Pipette

Quick Set Dials (also click on tabs below for further information)

 

Unlike traditional pipettes which utilize a single rotating plunger to set volumes, EVOLVE features one dial for setting each of three volume digits. This is the same convenient method used to unlock three dial combination locks.

This revolutionary approach allows users to set volumes more than ten times faster than standard manual pipettes. Simply depress and twist the plunger to unlock the quick set volume dials. Once unlocked, freely adjust the three dials to rapidly set the desired volume. Volumes set on traditional manual pipettes can often change while pipetting due to unintentional plunger turns.

The EVOLVE Quick Set Dial design prevents inadvertent volume drift due to plunger movements while pipetting.

EVOLVE Quick Set Dials

GripTip System

GripTip Pipette tips System

The rim of the GripTips will snap over the
Multi-Lobes, attaching firmly. As a result,
GripTips will never accidently fall off, even
after several touch-offs
.

 

A shoulder provides a positive stop to prevent over-tightening of the tip. The pipette tip cannot be advanced beyond the positive stop ensuring all tips are at the same height, thus
increasing the precision when touching off. That means, the tip is either on or off, but nothing in between. Hammering the pipette
into the tips to make sure they attach correctly is no longer required.

 

GripTips snap on
Do your pipette tips ever loosen, leak or fall off? This is a common issue in laboratories, caused by the use of universal pipette tips. Such tips require “hammering on” which stretches the shape of the pipette tip rim. The stretched pipette tip rim immediately starts moving back to its original shape, away from the tip cone. This can cause leaking, misaligned tips and even pipette tips that completely fall off the pipette!

This will never happen with any EVOLVE pipette / GripTip combination. Featuring a low attachment force and a low ejection force, GripTips effortlessly snap onto the tip fittings and are easily ejected. Also, GripTips feature a high lateral resistance once attached to the EVOLVE pipettes. This means GripTips are always firmly attached and perfectly aligned, regardless of how many side well touch offs are performed. You no longer have to hammer your pipette tips on or worry about pipette tips falling off!

(Click on image to enlarge)

Interchangeable Plunger Spring Assemblies

 

Two differently sized plunger springs allow users to customize the force needed to depress the plunger to their preference. The controlled plunger spring option allows users to slow the aspiration and dispense speeds resulting in improved pipetting technique and results.

The controlled plunger spring is compatible with all single channel EVOLVE pipettes except the 5 ml model. Changing the spring is completed in seconds.

3Interchangeable Plunger Spring Assemblies

INTEGRA Linear Stand

 

Storing pipettes upright is important to prevent liquid or debris from entering the tip fitting. Proper storage also extends the life of a pipette.

The INTEGRA linear stand is ideal for hanging EVOLVE pipettes up off the lab bench. Up to twelve manual pipettes can be placed on a linear stand. EVOLVE shelf hooks are also available for proper storage.

EVOLVE charging / communication station

 

INTEGRA linear stand

Watch Mason enjoying the benefits of the new EVOLVE pipette:

Video - EVOLVE Manual Pipettes - Simpleshow

EVOLVE volume setting explainer video:

Video - EVOLVE Manual Pipettes


Interview with Jonathan Harkins Product Manager EVOLVE Pipettes:

Specifications EVOLVE Manual Pipettes

Channel

Part No.

Volume Range (µl)

Volume
Increments (µl)

Test Volume
(µl)

Accuracy
(±%)

Precision
(≤%)

1

 

3011

0.2 - 2

0.001

0.2

12.00

6.00

 

1

3.00

1.60

2

1.80

1.00

3012

1 - 10

0.01

1

5.00

3.00

 

5

1.50

0.80

10

1.20

0.50

3013

2 - 20

0.01

2

7.00

2.00

 

10

1.60

0.50

20

1.20

0.35

3015

10 - 100

0.1

10

3.50

1.00

 

50

1.00

0.35

100

0.80

0.20

3016

20 - 200

0.1

20

2.50

1.00

 

100

1.00

0.30

200

0.70

0.18

3018

100 - 1000

1

100

3.00

0.60

 

500

1.00

0.30

1000

0.80

0.20

3019

500 - 5000

5

500

3.00

0.70

 

2500

1.20

0.30

5000

0.60

0.18

8

3022

1 - 10

0.01

1

12.00

7.00

 

5

4.00

3.00

10

2.00

1.20

3024

5 - 50

0.05

5

5.00

2.00

 

25

2.00

1.00

50

1.20

0.50

3025

10 - 100

0.1

10

5.00

2.00

 

50

2.00

0.80

100

1.20

0.50

3026

20 - 200

0.1

20

5.00

1.30

 

100

2.00

0.50

200

1.20

0.40

12

3032

1 - 10

0.01

1

12.00

7.00

 

5

4.00

3.00

10

2.00

1.20

3034

5 - 50

0.05

5

5.00

2.00

 

25

2.00

1.00

50

1.20

0.50

3035

10 - 100

0.1

10

5.00

2.00

 

50

2.00

0.80

100

1.20

0.50

3036

20 - 200

0.1

20

5.00

1.30

 

100

2.00

0.50

200

1.20

0.40

The pipettes specifications represent the performance of all channels of the pipettes.
Precision = Coefficient of Variation

 

Instruments (also click on tabs below for further information)

Click on image to enlarge Channels Volume range Part No.

EVOLVE
Manual Pipettes


EVOLVE Manual Pipetts

 

Single 0.2 - 2 μl 3011
1 - 10 μl 3012
2 - 20 μl 3013
10 - 100 μl 3015
20 - 200 μl 3016
100 - 1000 μl 3018
500 - 5000 μl 3019
Eight 1 - 10 μl 3022
5 - 50 μl 3024
10 - 100 μl 3025
20 - 200 μl 3026
12-channels 1 - 10 μl 3032
5 - 50 μl 3034
10 - 100 μl 3035
20 - 200 μl 3036
Single channel starter pack, includes 20, 200 and 1000 μl pipettes 3050
 

Accessories

EVOLVE Accessories
Multipurpose tool for calibration, O-ring removal and plunger spring exchange
3200
Shelf hook, 1/pack 3210
Shelf hook, 5/pack 3211
Plunger cap, black, 5/pack 3220
Plunger cap, purple (2, 10, 20 μl), 5/pack 3221
Plunger cap, yellow (50, 100 μl), 5/pack 3222
Plunger cap, green (200 μl), 5/pack 3223
Plunger cap, blue (1000 μl), 5/pack 3224
Plunger cap, orange (5000 μl), 5/pack 3225
Control spring assembly (for single channel pipettes 2, 10, 20, 100, 200 and 1000 μl only) 3230

Replacement O-rings

200 μl O-ring, tip fitting, replacement kit, 24/pack
100-00027-50
1000 μl O-ring, tip fitting, replacement kit, 24/pack 100-00028-50
5000 μl O-ring, tip fitting, replacement kit, 10/pack 100-00029-00

Linear Stand

EVOLVE Accessories
Linear Stand (Holds up to 4 charging stations, mains adapter and charging stations sold separate) 3215
Mains Adapter, for use with Linear Stand 3216
Charging Station for Linear Stand (incl. connection cable) 3217
Charging / communication station for linear stand (incl. connection cable and USB cable) 3218

GripTips

GripTips Tip size Description For use with Color
Code
Sterile
Filter
Sterile Non-
Sterile
INTEGRA GripTip pipette tips - Tip Racks with single inserts in 96 and 384 fold configuration
12.5 μl LONG 5 racks of 384 tips 2, 10, 12.5, 20 μl
4405 4404 4403
12.5 μl 5 racks of 384 tips 2, 10, 12.5, 20 μl
4415 4414 4413
125 μl 5 racks of 384 tips 50, 100, 125 µl
4425 4424 4423
300 μl 5 racks of 96 tips 200, 300 µl
4435 4434 4433
1250 μl 5 racks of 96 tips 1000, 1250 µl
4445 4444 4443
5000 μl 5 racks of 48 tips 5000 µl
4455 4454 4453
 
GREENCHOICE
Refills
Tip size Description For use with Color
Code
Pre-
Sterilized
Non-
Sterile
 
INTEGRA GripTip pipette tips - GREEN CHOICE refill system
12.5 μl LONG 5 inserts of 384 tips 2, 10, 12.5, 20 μl
4406 4402  
12.5 μl 5 inserts of 384 tips 2, 10, 12.5, 20 μl
4416 4412  
125 μl 5 inserts of 384 tips 50, 100, 125 µl
4426 4422  
300 μl 5 inserts of 96 tips 200, 300 µl
4436 4432  
1250 μl 5 inserts of 96 tips 1000, 1250 µl
4446 4442  
 
 
Bulk Packs Tip size Description For use with   Sterile Non-
Sterile
 
INTEGRA GripTip pipette tips - Bulk packs
12.5 μl LONG 1 bag of 1000 tips 2, 10, 12.5, 20 μl
- 4401  
12.5 μl 1 bag of 1000 tips 2, 10, 12.5, 20 μl
- 4411  
125 μl 1 bag of 1000 tips 50, 100, 125 µl
- 4421  
300 μl 1 bag of 1000 tips 200, 300 µl
- 4431  
1250 μl 1 bag of 500 tips 1000, 1250 µl
- 4441  
5000 μl 1 bag of 250 tips 5000 µl
- 4451  
5000 μl 1 bag of 100 tips,
individually wrapped
5000 µl
4456 -  
 
 
   
  © INTEGRA Biosciences AG. - Design by