VOYAGER II Pipettes - Speed up sample transfers between different labware

INTEGRA's VOYAGER II pipettes feature a unique motorized tip spacing, enabling parallel transfer of multiple samples between labware of different sizes and formats. The tip spacing can be changed by a simple push of a button. No manual adjustments or two handed operations are needed.

VIAFLO Voyager

Electronically Adjustable Tip Spacing (also click on tabs below for further information)

The VOYAGER II pipettes feature the only motorized adjustable tip spacing in the industry. By the push of a button it allows the tip spacing to expand anywhere between 4.5 mm and 33 mm (depending on the model). This enables access to a wide variety of labware, such as microplates, tube racks and gel boxes. Refer to the application tab for examples and a detailed description of the tip spacing options.

The motorized tip spacing offers many advantages over manual tip spacing adjustments:

  • Single handed operation leaves the other hand free to handle
        labware.
  • On the fly access to up to 3 user-defined tip spacings.
  • These user defined tip spacings are saved. No need to memorize
        spacings of different labware formats.
  • GripTip Pipette Tips

    GripTip Pipette tips System

    The rim of the GripTips will snap over the
    Multi-Lobes, attaching firmly. As a result,
    GripTips will never accidently fall off, even
    after several touch-offs
    .

     

    A shoulder provides a positive stop to prevent over-tightening of the tip. The pipette tip cannot be advanced beyond the positive stop ensuring all tips are at the same height, thus
    increasing the precision when touching off. That means, the tip is either on or off, but nothing in between. Hammering the pipette
    into the tips to make sure they attach correctly is no longer required.

     

    GripTips snap on
    Do your pipette tips ever loosen, leak or fall off? This is a common issue in laboratories, caused by the use of universal pipette tips. Such tips require “hammering on” which stretches the shape of the pipette tip rim. The stretched pipette tip rim immediately starts moving back to its original shape, away from the tip cone. This can cause leaking, misaligned tips and even pipette tips that completely fall off the pipette!

    This will never happen with any VOYAGER II electronic pipette / GripTip combination. Featuring a low attachment force and a low ejection force, GripTips effortlessly snap onto the tip fittings and are easily ejected. Also, GripTips feature a high lateral resistance once attached to the VOYAGER II pipettes. This means GripTips are always firmly attached and perfectly aligned, regardless of how many side well touch offs are performed. You no longer have to hammer your pipette tips on or worry about pipette tips falling off!

    (Click on image to enlarge)

    Touch Wheel Interface

    Intuitive operation and navigation

    The Touch Wheel interface offers a quick and ergonomic way to modify pipetting parameters. It enables you to browse through menus, change pipetting volumes and speeds or other settings.

    Instead of repeatedly pressing buttons or twisting fingers to modify volumes, you simply slide your finger over the Touch Wheel. Changing a dispense volume has never been so fast and easy!

     

    VIAFLO electronic pipette touch wheel interface

    Full Color Screen

    Easy to read display

    All INTEGRA pipettes feature full text menus, displaying pipetting protocols without abbreviations. This makes INTEGRA pipettes particularly easy to understand and intuitive to use.

    The entire menu structure is available in English, French, German, Spanish, Chinese and Japanese.

    Pipette screen multilingual

    (Click on image to enlarge)

    VIAFLO electronic pipette screen Currently active pipetting mode
    Next pipetting step is marked Aspiration volume
     

    Other parameters such as speed

     

    Various Pipetting Modes

    Immediately productive

    For the most common liquid handling tasks 10 preset pipetting programs are available, in which only basic parameters such as volume and speed need to be defined.

     
    • Pipet
    • Repeat Dispense
    • Sample Dilute
    • Pipet/Mix
    • Manual Pipet
    • Reverse Pipet
    • Variable Dispense
    • Variable Aspirate
    • Sample Dilute/Mix
    • Serial Dilution
     

    Customized pipetting programs

    For more elaborate pipetting protocols, up to 40 user defined custom programs can be created. The custom program is a step-based setup queuing liquid handling steps such as aspirate, dispense, mix and more.

     

    VIALINK Software

    Convenient pipette and program management

    INTEGRA electronic pipettes can be connected to VIALINK, a pipette management software. With VIALINK even complex custom programs can be quickly created and stored in a library on the computer, ensuring a backup is always available. Then, copy the programs onto your pipette to start your assay. 

    To connect a pipette to the PC and VIALINK, a charging / communication stand (4211) or a linear stand with charging /communication station (3215 and 3218) is required.

    For more information visit our VIALINK website.

    Vialink for convenient pipette and program management

    Time Savings

    Save hours of pipetting by using a VOYAGER II pipette!

    Instead of going back and forth with a single channel pipette between different  labware, the VOYAGER II allows you to transfer multiple samples at once. This increases pipetting productivity significantly, while also reducing pipetting errors, as the number of transfers is minimized.

    Transferring samples from 1.5 ml microcentrifuge tubes to a 96 well plate using a VOYAGER II multichannel pipette is 8 times faster compared to a single channel pipette.

    Tip Spacing and Labware Compatibility

    Normal multichannel pipettes have a fixed tip to tip spacing of 9 mm, which corresponds to the well to well spacing of a standard 96 well plate. However samples are usually stored, processed and analyzed in various labware formats, which makes it impossible to use normal multichannel pipettes for the entire workflow.

    VOYAGER II pipettes provide access to a wide range of labware formats, as their tip spacing can expand anywhere from 4.5 mm to 33 mm (depending on the model).

    The table below shows the possible minimum and maximum tip spacing for each VOYAGER II model and gives an indication which type of labware it can accomodate.

    VOYAGER II pipette tip spacing and examples of compatible labware

    (Click on image to enlarge)

    For example: an 8 channel 125 µl VOYAGER II pipette offers a tip spacing from 4.5 mm up to 14 mm. Typical tasks are plate reformatting between 96 well and 384 well plates or transfer samples between racked microcentrifuge tubes and plates (48/96/384 wells)
    .

    Typical Applications

    Gel loading
    Easily aspirate 8 or 12 samples from a 96 well PCR plate
    (9 mm spacing) and dispense to 4.5 mm spacing
    gel lanes.

    Plate reformatting
    Transferring samples between 96 and 384 well plates can be tedious and prone to transfer errors. VOYAGER II pipettes allow you to transfer 8 or 12 samples easily between 96 and 384 well plates (9 mm <-> 4.5 mm spacing).

     

    Transfer from tubes to plates
    Sample transfers from 1.5 ml microcentrifuge tube
    racks (~14 mm spacing) to microplates is a routine
    task for a VOYAGER II pipette and saves many transfer steps.

    Cell seeding
    The 4 and 6 channel VOYAGER II pipettes accommodate even the large well to well spacing of 12 and 24 well plates (26 mm and 19 mm). This allows you to transfer cells at a fraction of the time it would take with a single channel pipette.

    Watch Video

    Part #

    Channels

    Volume Range
    (µl)

    Increments
    (µl)

    Spacing
    (mm)

    Test Volume (µl)

    Accuracy
    (± %)

    Precision
    (≤ %)

    4743

    4

    10 – 300

    0.50

    9.0 – 33.0

    30

    4.00

    1.20

    150

    2.00

    0.60

    300

    1.60

    0.35

    4744

    4

    50 – 1250

    1.00

    9.0 – 33.0

    125

    6.00

    1.10

    625

    2.40

    0.50

    1250

    1.20

    0.30

    4763

    6

    10 – 300

    0.50

    9.0 – 19.8

    30

    4.00

    1.20

    150

    2.00

    0.60

    300

    1.60

    0.35

    4764

    6

    50 – 1250

    1.00

    9.0 – 19.8

    125

    6.00

    1.10

    625

    2.40

    0.50

    1250

    1.20

    0.30

    4721

    8

    0.5 – 12.5

    0.01

    4.5 – 14.1

    1.25

    10.00

    6.00

    6.25

    4.00

    1.60

    12.5

    2.00

    0.80

    4726

    8

    2 50

    0.05

    4.5 – 14.1

    5.0

    5.00

    2.50

    25.0

    2.50

    0.60

    50

    1.50

    0.40

    4722

    8

    5 – 125

    0.10

    4.5 – 14.1

    12.5

    3.75

    1.50

    62.5

    2.50

    0.70

    125

    1.60

    0.35

    4723

    8

    10 – 300

    0.50

    9.0 – 14.1

    30

    4.00

    1.20

    150

    2.00

    0.60

    300

    1.60

    0.35

    4724

    8

    50 – 1250

    1.00

    9.0 – 14.1

    125

    6.00

    1.10

    625

    2.40

    0.50

    1250

    1.20

    0.30

    4731

    12

    0.5 – 12.5

    0.01

    4.5 – 9.0

    1.25

    10.00

    6.00

    6.25

    4.00

    1,60

    12.5

    2.00

    0.80

    4736

    12

    2 – 50

    0.05

    4.5 – 9.0

    5.0

    5.00

    2.50

    25.0

    2.50

    0.60

    50

    1.50

    0.40

    4732

    12

    5 – 125

    0.10

    4.5 – 9.0

    12.5

    3.75

    1.50

    62.5

    2.50

    0.70

    125

    1.60

    0.35

    Instruments (also click on tabs below for further information)

      Number of channels Volume Range Part No.

    VOYAGER II Electronic Pipettes*

    4-channels 10 – 300 μl 4743
    50 – 1250 μl 4744
    6-channels 10 – 300 μl 4763
    50 – 1250 μl 4764
    8-channels 0.5 – 12.5 μl 4721  
    2 –  50 μl 4726  
    5 – 125 μl 4722  
    10 – 300 μl 4723  
    50 – 1250 μl 4724  
    12-channels

    0.5 – 12.5 µl

    4731

     
    2 – 50 μl 4736  

    5 – 125 μl

    4732  
     
    *power supply not included

    Charging options and battery

    Charging Options

     

    Part No.

         
    Mains Adapter


    Directly charge the pipette using a mains adapter. Pipette can be used while charging.

    4200

       
    Single pipette charging
    stand

    Elegant charging stand for one pipette.

    4210

       
    Charging / Communication stand


    In addition to charging pipettes, this stand enables the communication of a pipette with a PC and VIALINK.

    4211

       

     

    Carousel stand for 4
    pipettes

    The space saving carousel stand accommodates 4 electronic pipettes for charging. 4215

     

     

     

    Linear stand

    The linear stand accommodates all types of INTEGRA pipettes.
    It can be converted to a charging stand by attaching up to four charging stations. In addition, a mains adapter (3216) is required.
    3215
     

    Linear stand accessories:

         
    Mains adapter This mains adapter is required to convert the linear stand into a charging station. 3216
         

    Charging station

    Attach up to four charging stations to the linear stand to convert it into a charging stand.

    3217

         
    Charging / Communication station

    In addition to charging, this station enables the communication of a pipette with a PC and VIALINK. Up to four charging / communication stations can be attached to the linear stand.

    3218

     

     

     

    Battery    
         

    Pipette battery

    Li-ion battery

    4205

         
     

    Replacement O-rings

    300 μl O-ring, tip fitting, replacement kit, 24/pack
    100-00027-50
    1250 μl O-ring, tip fitting, replacement kit, 24/pack 100-00028-50
    5000 μl O-ring, tip fitting, replacement kit, 10/pack 100-00029-00

    Grip Tips and Reagent Reservoirs

    Click on image to enlarge     Part No. Part No. Part No.

    GripTips

    Griptips Pipette tips

    Tip Size Description Filter Sterile Sterile Non-Sterile
    12.5 μl LONG 5 racks of 384 GripTips 4405 4404 4403
    12.5 μl 5 racks of 384 GripTips 4415 4414 4413
    50/125 μl 5 racks of 384 GripTips 4425 4424 4423
    300 μl 5 racks of 96 GripTips 4435 4434 4433
    1250 μl 5 racks of 96 GripTips 4445 4444 4443
     
            Pre-Sterilized Non-Sterile

    GREENCHOICE Refills

    GripTip Pipette Tips Green Choice

    12.5 μl LONG 5 inserts of 384 GripTips 4406 4402
    12.5 μl 5 inserts of 384 GripTips 4416 4412
    50/125 μl 5 inserts of 384 GripTips 4426 4422
    300 μl 5 inserts of 96 GripTips 4436 4432
    1250 μl 5 inserts of 96 GripTips 4446 4442
     
            Sterile Non-Sterile

    Bulk packaging

    GripTip Pipette Tips bulk packs

    12.5 μl LONG 1 bag of 1000 GripTips     4401
    12.5 μl 1 bag of 1000 GripTips     4411
    50/125 μl 1 bag of 1000 GripTips     4421
    300 μl 1 bag of 1000 GripTips     4431
    1250 μl 1 bag of 500 GripTips     4441
     
     
      Volume       Part No.

    Reagent reservoirs

    INTEGRA Reagent reservoir

    10 ml Reservoir base, 10 bases per case 4306
    Disposable reservoirs, 30 individually sealed, sterile 4331
    Disposable reservoirs, 4 sleeves of 50, sterile 4332
    25 ml Reservoir base, 10 bases per case 4304
    Disposable reservoirs, 30 individually sealed, sterile 4311
    Disposable reservoirs, 4 sleeves of 50, sterile 4312
    100 ml Reservoir base, 10 bases per case 4305
    Disposable reservoirs, 30 individually sealed, sterile 4321
    Disposable reservoirs, 4 sleeves of 50, sterile 4322
     
    Testimonials  
    Customer testimonial video - VOYAGER adjustable spacer pipette

    VOYAGER pipette boosts throughput for screening applications and genotyping
    Christina Thomas works at the Institute of Clinical Chemistry research group at the Technical University of Munich (TUM). In this short video, she shows and explains how the VOYAGER pipette helps her and the entire team to increase the throughput for screening applications and genotyping significantly.

    Watch video

    Video - qRT-PCR Assay Setup using VOYAGER

    qRT-PCR Assay Setup using VOYAGER

    Pipetting 64 samples in triplicate for two genes of interest (GOI) all under 10 minutes!

    Watch Video

     
       