MEDIACLAVE 10 media sterilizer

MEDIACLAVE 10/30 Media Sterilizer

Media Sterilizer

Product story

Fast, reproducible and safe media sterilization

The preparation of agar medium is a routine task in today’s laboratories. The typical workflow is to dissolve the components in a flask followed by sterilization in an autoclave. However, this procedure has several disadvantages.

First, the numerous working steps makes media preparation very time-consuming. Second, the sterilization temperature is usually controlled only in one single reference container, with the result that heat exposure may differ from sample to sample. Making things worse, the agar medium within the bottles cannot be stirred during the sterilization process – which otherwise would guarantee that it stays homogeneous. Lastly, it takes very long to cool the medium to dispensing temperatures and hence is exposed to a high temperature for a long time. As a result, the fertility of the agar medium might be impaired.

INTEGRA has designed a dedicated media sterilizer which eliminates these disadvantages. MEDIACLAVE allows for a much shorter process in which medium formulation and sterilization is carried out in one single step. The temperature of the agar medium is precisely monitored and controlled during the entire process. Permanent stirring guarantees homogenous temperature throughout the whole batch and an efficient plate heat exchanger facilitates rapid cooling. All these features prevent the medium from excessive heat exposure and thereby maintains its fertility.

How it Works

How it works

The MEDIACLAVE product range allows the rapid and gentle preparation of 1 – 30 L culture medium. Precise controlling and monitoring of temperature, time and pressure during the sterilization process guarantee constant high quality.

  • Safety

    MEDIACLAVE 10/30 media sterilizers feature several independent safety elements

    MEDIACLAVE is equipped with several independent monitoring systems for pressure and temperature, guaranteeing highest safety standards for the user and the working environment. The vessel lid is equipped with an autonomous overpressure safety valve and a burst disc in case all other electronic monitoring systems fail.

    1) Adding Port
    2) Overpressure Safety Valve
    3) Dispensing Port
    4) Temperature Probe Pt1000

  • Fast Heating and Rapid Cooling

    Graph of typical sterilization cycle using MEDIACLAVE media preparator

    Powerful heating elements permit fast media processing. This minimises thermal stress and ensures high fertility of your culture medium. Pressure and temperature controlled deaeration guarantees saturated steam in the vessel.

    Rapid cooling is enabled by an efficient plate heat exchanger. The separation of the cooling water system and the sterilization chamber makes it unlikely that culture media gets contaminated by cooling water.

    1) Standard mode: Heating up, sterilization and cooling down to dispensing temperature.
    2) Chocolate agar mode: After the first sterilization phase, blood is added and the medium heated up again.

  • Reliable Sterilisation

    MEDIACLAVE media sterilizers feature strong magnetic stirrer and a Pt-1000 temperature probe

    The large and strong magnetic stirrer with adjustable speed and reversing rotation direction ensures homogenous media preparation over a wide viscosity range. A Pt-1000 temperature probe and microprocessor control of process parameters allow reproducible and complete sterilization of culture media.

  • Dispensing

    MEDIAJET Petri dish filler is a perfect complement to MC10/30

    MEDIACLAVE can be quickly and conveniently connected to the dispensing tubing of the automated Petri dish filler MEDIAJET. Alternatively, the peristaltic pump DOSE IT can be used to fill containers of more unusual volumes or shapes, e.g. quadrangular Petri dishes, bottles or flasks.

    Large containers such as bottles can be filled by pressure dispensing. Medium is dispensed by automatically building up pressure inside the sterilization chamber.

  • Process documentation and validation

    MEDIAJET process documentation

    The MEDIACLAVE sterilization process is monitored and can be stored on a PC. A digital signature according to FDA (21 CFR Part 11) / EU (GMP Annex 11) is automatically added to the electronic process file. All logfiles can also be stored using the MEDIACLAVE USB port.

    If equipped with an optionally available dot matrix printer, high quality printouts insusceptible to fading can be archived.

Customer Voices

Customer Voices

    •  
    •  
    •  
    •  
    •  

    excellent

    "The Mediaclave and MediaJet plating systems helps me a lot in my current job. With the Mediaclave autoclave, I can reduce the risk compared to conventional autoclaves, ensuring the autoclaving temperature of the culture medium. With the plating system, our lab reduces manual operations, avoiding cro..."

    Hieu Pham

    SGS TNHH Viet Nam

    •  
    •  
    •  
    •  
    •  

    Amazing

    "It's very important tool for the laboratory department "

    Naveen Gopi Manakkadan

    RPM

    •  
    •  
    •  
    •  
    •  

    Great performance and reliability

    "We bought a MediaClave 10, and it has been performing excellently for 10+ years. Recently, we bought a 2nd one. It is the easiest way to prepare culture plates."

    Eulalia Martinez

    FUCHS Lubricantes SAU

See it Work

See it work

Apps

Uses and Applications

Overview Applications Stories

Applications

Standard Agar medium
Standard Agar medium

MEDIACLAVE used for the preparation and sterilization of numerous types of culture media

Typical examples are:

  • LB (Luria Bertani) Medium – primarily used for the cultivation of Escherichia coli
  • Tryptic Soy Agar – general purpose medium used for culturing a wide array of microorganisms
  • Blood Agar – for fastidious microorganisms
  • Chocolate Agar – for fastidious respiratory bacteria such as Haemophilus influenzae
  • MacConkey Agar – for Gram-negative bacteria
  • Sabouraud Agar – for fungi
  • Peptone solutions – for sample preparation
Standar Agar media sterilized and filled into Petri dishes
MEDIACLAVE used for culture media preparation
Charcoal Agar
Charcoal Agar

Preparing Charcoal Agar Medium using MEDIACLAVE

Charcoal Agar is used for the cultivation and isolation of Bordetella pertussis and Haemophilus influenza among others. Using a stirrer bar with paddles, high-viscosity Charcoal Agar can be prepared without the need of pre-swelling. Preparation time is reduced by more than 30 percent.

Benefits using MEDIACLAVE with paddle stirrer:

  • Improved mixing performance
  • Minimized foaming
  • Shorter preparation time
Fly food preparation
Fly food preparation

An optimized system for the preparation of Drosophila melanogaster (fly) food

MEDIACLAVE is an attractive alternative to simple cooking pots or stirrer kettles often used for preparing Drosophila (fly) food. With its integrated cooling system, MEDIACLAVE eliminates the need to wait several hours until the fly food is cooled to dispensing temperature. In no more than 90 minutes, the mixture is ready to dispense. In addition, the fly food is kept at the desired dispensing temperature

Tech Info

Tech info

Find here a quick overview of the product specifications. More detailed information can be found in the download-section below.

Capacity
MC 10: 1-10 litres; MC 30: 3-30 litres
Dimensions (HxWxD)
MC 10: 480 x 550 x 640 mm; MC 30: 1040 x 550 x 640 mm
Weight
MC 10: 57 kg; MC 30: 85 kg
Downloads & More Parts and Numbers

Parts and numbers

Instruments
Instruments

MEDIACLAVE 10 and MEDIACLAVE 30

MEDIACLAVE 10

10 Litres Media Preparator complete with cuvette, lid seal, magnetic stirrer, decanting tubing, fitting for dispensing tubing, integrated printer and printer splash guard (200 – 240 V, 50/60 Hz).

PlugPart No.
EU (CEE 7/7)136000
US (NEMA L6-30P)136010
No plug136020

MEDIACLAVE 10 (without printer)

10 Litres Media Preparator complete with cuvette, lid seal, magnetic stirrer, decanting tubing, fitting for dispensing tubing (200 – 240 V, 50/60 Hz).

PlugPart No.
EU (CEE 7/7)136005
US (NEMA L6-30P)136015
No plug136025
MEDIACLAVE 10 media sterilizers with and without printer
MEDIACLAVE 10 with/without printer

MEDIACLAVE 30

30 Litres Media Preparator complete with cuvette, lid seal, magnetic stirrer, decanting tubing, fitting for dispensing tubing, integrated printer and printer splash guard.

VoltagePart No.
3 x 200 – 208 V, 50/60 Hz (US, JP) - with plug136050
3 x 400 V, 50/60 Hz (EU) - without plug136055
MEDIACLAVE 30 media sterilizer
MEDIACLAVE 30 media preparator
Accessories for MEDIACLAVE 10
Accessories for MEDIACLAVE 10

Cuvettes, stirrer bars, adapters, etc.

DescriptionPart No.
Stainless steel cuvette for medium sterilization136030
Autoclave kit for autoclaving/thermostatting liquids in containers, incl. autoclave cuvette, stainless steel with grid insert and flexible temperature probe136070
Magnetic stirrer bar for homogeneous medium mixing within the cuvette132130
Magnetic stirrer bar with paddle for homogeneous stirring of high viscosity agar medium136075
Decanting tubing for insertion into the cuvette for dispensing, incl. Silicone tubing, stainless steel nozzle and securing nut136034
Fitting for dispensing tubing for connecting tubing (inner diameter 6 mm) to dispense port, incl. stainless dispense port fitting and spring136035
Printer splash guard for protecting the integrated printer from splashes136040
Tubing connector for adding port, for adding volumes of supplements through the adding port using a silicone tubing (inner diameter 6 mm) and a peristaltic pump136049
Injection lid for sterile injection of supplements though the adding port, incl. cap, punched disc and septum membrane (silicone/PTFE)136247
Pressure dispensing kit for direct pressure dispensing, incl. Pinch valve box, foot switch, silicone tubing and stainless steel dispensing tube136064
Dispensing tube for pressure dispensing, inner diameter 6 mm, length 10 cm, stainless steel, one end dented171056
Foot switch with connecting cable for pressure dispensing, to trigger the pinch valve143200
Accessories for MEDIACLAVE 30
Accessories for MEDIACLAVE 30

Cuvettes, stirrer bars, adapters, etc.

DescriptionPart No.
Stainless steel cuvette for medium sterilization, incl. stainless steel guide tube for temperature probe136060
Magnetic stirrer bar with paddle for homogeneous stirring136075
Decanting tubing for insertion into the cuvette for dispensing, incl. rigid stainless steel tube (length 613 mm), silicone tubing and securing nut136061
Fitting for dispensing tubing for connecting tubing (inner diameter 6 mm)136035
Printer splash guard for protecting the integrated printer from splashes136040
Tubing connector for adding port, for adding volumes of supplements through the adding port using a silicone tubing (inner diameter 6 mm) and a peristaltic pump136049
Injection lid for sterile injection of supplements though the adding port, incl. cap, punched disc and septum membrane (silicone/PTFE)136247
Pressure dispensing kit for direct pressure dispensing, incl. Pinch valve box, foot switch, silicone tubing and stainless steel dispensing tube136064
Dispensing tube for pressure dispensing, inner diameter 6 mm, length 10 cm, stainless steel, one end dented171056
Foot switch with connecting cable for pressure dispensing, to trigger the pinch valve143200
Volume measuring stick for convenient measurement of the product volume in the cuvette136565
Consumables
Consumables

Consumables for MEDIACLAVE 10 and MEDIACLAVE 30

DescriptionPart No.
Lid seal for sealing the vessel lid, silicone135860
Pivot Pin Disk for cuvette 10/30 L, PTFE, 6-pack136066
Septum membrane for injection lid, silicone/PTFE, self-resealing, 10-pack136047
Paper rolls for integrated dot matrix printer, 10-pack136038
Ink ribbon for integrated dot matrix printer136901
Silicone tubing for pressure dispensing, length 25, (bulk roll), inner diameter 6 mm, autoclavable171036