Affordable, high throughput bulk RNA barcoding and sequencing plate preparation with the VIAFLO 384

  • Affordable, high throughput bulk RNA barcoding and sequencing plate preparation with the VIAFLO 384

    Streamline BRB-seq preparation with the VIAFLO 384

    3ʹ mRNA-seq is an effective tool for measuring gene expression in an unbiased and quantitative manner. However, existing technologies are too laborious and expensive to be applied to large scale projects with numerous samples. Alithea Genomics has developed a novel, proprietary technology called bulk RNA barcoding and sequencing (BRB-seq), which enables the streamlined preparation of 3ʹ mRNA-seq libraries for hundreds of RNA samples in a single tube. The cornerstone of this technology is the use of BRB-seq oligos, which are synthetic DNA oligonucleotides.

    BRB-seq oligos prime the reverse transcription (RT) reaction, during which the unique molecular identifier (UMI) and the sample-specific barcode are integrated into the synthesized complementary DNA (cDNA) strand. The use of BRB-seq oligos enables the molecular ‘tagging’ of individual RNA samples. After this initial tagging step, all samples (up to 384) can be pooled and processed simultaneously in a single tube for the rest of the workflow.

    Alithea Genomics provides kits that contain all the reagents necessary to perform BRB-seq on different sample types, including purified RNA, whole-blood RNA, and cell/organoid lysates.

    The combination of the BRB-seq kits with the VIAFLO 96 and VIAFLO 384 systems provides a convenient, efficient and reliable workflow for massively multiplexed RNA-seq experiments.

  • Table of contents

    3ʹ mRNA-seq is an effective tool for measuring gene expression in an unbiased and quantitative manner. However, existing technologies are too laborious and expensive to be applied to large scale projects with numerous samples. Alithea Genomics has developed a novel, proprietary technology called bulk RNA barcoding and sequencing (BRB-seq), which enables the streamlined preparation of 3ʹ mRNA-seq libraries for hundreds of RNA samples in a single tube. The cornerstone of this technology is the use of BRB-seq oligos, which are synthetic DNA oligonucleotides.

    BRB-seq oligos prime the reverse transcription (RT) reaction, during which the unique molecular identifier (UMI) and the sample-specific barcode are integrated into the synthesized complementary DNA (cDNA) strand. The use of BRB-seq oligos enables the molecular ‘tagging’ of individual RNA samples. After this initial tagging step, all samples (up to 384) can be pooled and processed simultaneously in a single tube for the rest of the workflow.

    Alithea Genomics provides kits that contain all the reagents necessary to perform BRB-seq on different sample types, including purified RNA, whole-blood RNA, and cell/organoid lysates.

    The combination of the BRB-seq kits with the VIAFLO 96 and VIAFLO 384 systems provides a convenient, efficient and reliable workflow for massively multiplexed RNA-seq experiments.

Key benefits

  • The BRB-seq workflow requires a very precise pipetting system, such as the VIAFLO 96 or VIAFLO 384, for simultaneous transfer of small volumes of 96 or 384 samples from one plate to another.
  • The 96 and 384 channel pipetting heads are interchangeable on the VIAFLO 384 handheld electronic pipette, providing the user the flexibility to transfer 96 or 384 samples in a single step.
  • Processing thousands of samples for BRB-seq can be drastically accelerated by using the VIAFLO 96 or VIAFLO 384 handheld electronic pipettes.
  • High quality GRIPTIPS® provide a perfect tip seal. This guarantees that all tips on the VIAFLO 96 or VIAFLO 384 are at exactly the same height and will never fall off accidentally. This ensures increased accuracy and precision for liquid handling steps.

Downloads: App note and protocol for the affordable, high throughput bulk RNA barcoding and sequencing plate preparation with the VIAFLO 96 or VIAFLO 384

Here you can download the complete protocol used in this application and use them on your VIAFLO 96 or VIAFLO 384. The protocol can be customized with the VIALINK software.

Overview: How to prepare samples for BRB-seq

Early-stage multiplexing is possible because of the highly optimized sets of barcoded primers (BRB-seq oligos), which are added during the RT reaction (Figure 1).

The structure of Alithea Genomics’ barcoded oligonucleotides
Figure 1: The barcoded oligo-deoxythymidines (dT) are attached at the RT step.

Step-by-step procedure:

Either the VIAFLO 96 or VIAFLO 384 can be used for the main pipetting steps during sample preparation for BRB-seq. The instruments are equipped with a 96 or 384 channel pipetting head (0.5-12.5 µl) and a three position stage (with positions A, A/B, and B). 12.5 µl Sterile, Filter GRIPTIPS are used. Pre-washed cells (in a 96 well or 384 well Sample plate) are lysed with 10 or 5 µl cell lysis buffer (respectively). Customized VIALINK programs are provided for the cell lysate transfers and pooling steps (Figure 2, steps 2, 3 and 7) in 384 well plates. The custom VIALINK programs for 96 well plates are available in the download section.  

 

Overview of the programs:

  • Program 1: Transfer the cell lysates to the Stock plate – Cell lysate transfer
  • Program 2: Transfer the cell lysates to the Barcode plate – Barcoding
  • Program 3: Pooling of samples after RT reaction – Pooling
Sample preparation workflow for cell lysate BRB-seq with the help of the VIAFLO 384.
Figure 2: The sample preparation workflow for cell lysate BRB-seq of 384 samples (green arrows show the transfer steps of the VIAFLO 384).

1. Cell lysate transfer

Transfer of cell lysates to the Stock plate.

Load a full box of 12.5 µl Sterile, filter GRIPTIPS onto the VIAFLO 384. Slide the three position stage to the left so that it is in the second position (A/B-B). Launch the custom program '384 LYS STORAGE'. A prompt on the pipette screen informs the user that the Sample plate (384 well cell culture plate, Corning) should be placed on position A/B, and the Stock plate – a new 384 well PCR plate (Eppendorf) placed on 384 well cooling block – on position B (Figure 3). The pipetting head should then be lowered and the pipette tips should be placed into the individual wells of the Sample plate. The pipette aspirates 7 µl of cell lysate from the wells of the Sample plate and dispenses it to the wells of the Stock plate. When the dispense step is finished, if more samples are to be transferred, the pipette will notify the user that the pipette tips need to be changed and the program restarted. Alternatively, if there are no further samples to transfer, the pipette will notify the user that the program is finished. The Stock plate can then be kept at -80 °C for later analysis or used immediately for continuation of the workflow.

Tips:

  • The aluminum 384 (or 96) well PCR cooling block keeps the samples or reagents chilled.
  • The Z-heights are defined in the programs to ensure optimal tip immersion depth.
A close-up of the VIAFLO 384 handheld electronic pipette transferring cell lysate from a 384 well cell culture plate.
Figure 3: The three position stage of the VIAFLO 384 set-up for the cell lysate transfer step.

2. Barcoding

Transfer of cell lysates to the Barcode plate.

Load a full box of new 12.5 µl Sterile, Filter GRIPTIPS onto the VIAFLO 384. Move the three position stage to the second position (A/B-B). Select the custom program ‘384_LYS_OLIGOS’. The instrument will display the prompt that the Stock plate (on a 384 well cooling block) needs to be placed on position A, and the Barcode plate (on a 384 well cooling block) on position B. The pipetting head with the tips should then be lowered into the individual wells of the Stock plate (Figure 4). The VIAFLO 384 aspirates 5 µl of the cell lysate from each well of the Stock plate, and dispenses it to the Barcode plate that contains the optimized barcoded oligos. After the dispense step, if new cell lysates are to be transferred to new Barcode plates, the pipette informs the user that the pipette tips need to be changed. Alternatively, if there are no further samples to transfer, the pipette informs the user that the program is finished.

After adding the cell lysate to the barcodes, 10 µl of RT mix should be added manually with a 16 channel (12 channel in the case of 96 well plate) VIALFO pipette from PCR strip tubes (Starlab). The Reaction plate containing the cell lysates, the barcodes, and the RT mix needs to be transferred to a thermal cycler and incubated at 50 °C for 30 min.

A close-up of the VIAFLO 384 handheld electronic pipette transferring cell lysate to a plate containing the barcoded oligos.
Figure 4: The three position stage of the VIAFLO 384 set-up for the barcoding step.

3. Pooling

Pooling of samples after RT reaction.

After incubation, the barcoded cDNA samples can be pooled together. Load a full box of new 12.5 µl Sterile, Filter GRIPTIPS, slide the three position stage to the second position (A/B-B), and start the custom program '384 POOLING'. The pipette tells the user to place the Reaction plate (on the cooling block) on position A, an INTEGRA 150 ml automation-friendly reservoir on position B, and to lower the pipetting head with the tips into individual wells of the reaction plate (Figure 5). The pipette then aspirates 10 µl solution from each well, and dispenses it to the reservoir.

A close-up of the VIAFLO 384 handheld electronic pipette pooling together cDNA samples in a reservoir.
Figure 5: The three position stage of the VIAFLO 384 set-up for the pooling step.

4. Collecting the pool

Transferring the pool to a vessel.

The pool can be transferred to a 15 ml centrifuge tube (Greiner Bio-one) for further precleaning. This process can be easily executed with INTEGRA's PIPETBOY acu 2. The pool is ready for subsequent library preparation and next generation sequencing.

 

5. Results

Sample results obtained using either the BRB-seqTM kit, or the Cell lysate BRB-seqTM kit, and the VIAFLO 384 channel handheld electronic pipettes are shown below.

Graphical representation of the number of genes detected with BRB-seq across 384 purified RNA samples.
Figure 6: Distribution of the number of detected genes across 384 samples processed in one tube, using Alithea's MERCURIUS™ BRB-seq kit. The library was sequenced at an average of 1 million reads per sample.
Graphical representation of the number of genes detected with BRB-seq across 384 cell lysates.
Figure 7: Distribution of the number of detected genes across 384 samples processed in one tube, using Alithea's MERCURIUS™ cell lysates BRB-seq kit. The library was sequenced at an average of 1.5 million reads per sample.

Conclusion

  • 'Large scale' and 'high throughput' are often synonyms of bulky, expensive, and fully automated liquid handling solutions. By combining Alithea Genomics' BRB-seq technology with the VIAFLO 96 or VIAFLO 384, we demonstrate that there is an easier way to achieve a reliable, ultra-high throughput and cost-efficient RNA-seq workflow.
  • With BRB-seq, up to 384 RNA or cell lysate samples can be processed in a single tube, right from the beginning of the library preparation workflow. With the VIAFLO 96 and 384 systems, the large number of pipetting steps can be condensed into handful of semi-automated plate-to-plate transfers.
  • Setting the Z-height and the Tip Align on the VIAFLO 96 and VIAFLO 384 minimizes pipetting variability.
  • Thanks to the compact benchtop design, both the VIAFLO 96 and VIAFLO 384 can fit into most laminar flow hoods, or on a small bench.
  • Large scale RNA-seq is becoming an important tool that biotech, pharma and academic institutes can use to discover and develop new drugs. Performing this large-scale RNA-seq using BRB-seq and the VIAFLO 96 or VIAFLO 384 drastically reduces the turnaround times and operational costs.
  • Using the BRB-seq kits on the VIAFLO 96 or VIAFLO 384 offers a convenient, compact and cost-effective solution to unlock the power of large scale RNA-seq.

Related articles

Ask our expert. Leave a comment!

Write us if you have any questions regarding the application note or one of our instruments.

Any questions? I'm happy to help!

  • Éva Mészáros, PhD

    Application Specialist

    Email

Instruments and accessories

VIAFLO 96/ VIAFLO 384, Handheld Electronic Pipette 96 Channel Pipetting Heads 384 Channel Pipetting Heads PIPETBOY acu 2 VIAFLO 12 channel, 0.5 - 12.5 µl, electronic pipette VIAFLO 16 channel, electronic pipette Three position stage for 96 and 384 well plates PCR 96 well cooling block PCR 384 well cooling block GRIPTIPS®, 12.5 µl, Sterile, Filter GRIPTIPS®, 12.5 µl Pre-sterilized, Filter Automation Friendly Reservoir, Polypropylene, Sterile, 150 ml Greiner Bio-One: Tube, 15 ml, PP STARLAB: 8-Strip Non-Flex PCR Tubes, 0.2 ml Eppendorf: twin.tec® PCR Plate 96 Eppendorf: twin.tec® PCR Plate 384 Greiner Bio-One: Cellculture microplate, 96 well, PS, F-bottom CORNING: 384 well clear flat bottom polystyrene TC-treated microplate ALITHEA GENOMICS: MERCURIUS™ BRB-seq Library preparation kits for Illumina® ALITHEA GENOMICS: MERCURIUS™ Cell lysate BRB-seq Library preparation kits for Illumina®

VIAFLO 96/ VIAFLO 384, Handheld Electronic Pipette

With this 24, 96 and 384 channel pipette, INTEGRA meets the need for an affordable, compact and easy to use pipette that provides increased productivity. The unique operating concept makes VIAFLO 96/384 as easy to use as any traditional handheld pipette.

Part No. 6001 / 6031

See how it works
The VIAFLO 96/384 is handheld, electronic pipette

96 Channel Pipetting Heads

Users can simply change the pipetting head of their VIAFLO 96 and VIAFLO 384 to guarantee optimal matching of the available volume range to the application performed. Changing a pipetting head of VIAFLO 96 and VIAFLO 384 is easy and takes less than one minute.

Part No. 6101 (0.5 - 12.5 µl)
Part No. 6102 (5 - 125 µl)
Part No. 6103 (10 - 300 µl)
Part No. 6104 (50 - 1250 µl)
Part No. 6106 (2 - 50 µl)

Find out more about VIAFLO 96/384 Pipetting Heads Specifications
VIAFLO 96/384 96 channel pipetting head

384 Channel Pipetting Heads

Users can simply change the pipetting head of their VIAFLO 96 and VIAFLO 384 to guarantee optimal matching of the available volume range to the application performed. Changing a pipetting head of VIAFLO 96 and VIAFLO 384 is easy and takes less than one minute.

Part No. 6131 (0.5 - 12.5 µl)
Part No. 6132 (5 - 125 µl)
Part No. 6136 (2 - 50 µl)

Find out more about 384 Channel Pipetting Heads
384 Channel Pipetting Heads

PIPETBOY acu 2

The most popular Pipette Controller

  • Precise and efficient serological pipetting
  • Unmatched speed and  pipetting control
  • Surpassing ergonomics

Part No. 155000

See it work
PIPETBOY acu 2 pipette controllers in 9 different colors

VIAFLO 12 channel, 0.5 - 12.5 µl, electronic pipette

The Touch Wheel is a quick and ergonomic way to modify pipetting parameters. Instead of repeatedly pushing buttons or twisting fingers to modify volumes, you simply slide your finger over the wheel.

The full color screen provides full text menus (in multiple languages) and displays pipetting protocols without abbreviations, making VIAFLO pipettes particularly easy to understand and intuitive to use.

Part No. 4632

Find out more about VIAFLO electronic pipettes
INTEGRA’s range of VIAFLO electronic pipettes.

VIAFLO 16 channel, electronic pipette

The Touch Wheel is a quick and ergonomic way to modify pipetting parameters. Instead of repeatedly pushing buttons or twisting fingers to modify volumes, you simply slide your finger over the wheel.

The full color screen provides full text menus (in multiple languages) and displays pipetting protocols without abbreviations, making VIAFLO pipettes particularly easy to understand and intuitive to use.

Part No. 4641 (0.5 - 12.5 µl)
Part No. 4642 (5 - 125 µl)
Part No. 4646 (2 - 50 µl)

Find out more about VIAFLO electronic pipettes
INTEGRA’s range of VIAFLO electronic pipettes.

Three position stage for 96 and 384 well plates

This accessory expands available stage positions for microplates, reservoirs and tips on a VIAFLO 96 or VIAFLO 384 from 2 to 3 thereby enhancing workflow in a wide range of applications. Beneficially the Three Position Stage also features an indexing function to allow access to 384-well plates using a 96-channel pipetting head.

Part No. 6230

See all plate holder options
Three position stage for 96 and 384 channel pipetting

PCR 96 well cooling block

Aluminium 96 and 384 well PCR cooling blocks that keep reagents chilled during sample preparation in a PCR plate. The cooling blocks feature a SBS footprint.

Part No. 6250

Find more labware accessories
PCR cooling block

PCR 384 well cooling block

Aluminium 96 and 384 well PCR cooling blocks that keep reagents chilled during sample preparation in a PCR plate. The cooling blocks feature a SBS footprint.

Part No. 6255

Find more labware accessories
384-well PCR cooling plate

GRIPTIPS®, 12.5 µl, Sterile, Filter

GRIPTIPS® pipette tips perfectly match the multi-lobe tip fitting, snapping firmly on during loading. This guarantees a perfect seal on every tip, preventing them from loosening, leaking or completely falling off. All tips are precisely aligned horizontally, enabling accurate touch-offs, even when pipetting with 384 tips.

Part No. 4415

Learn more about GRIPTIPS® pipette tips for Benchtop Pipetting Systems
Integra-Relaunch_Website-Output-Produktebilder-Product_Overview-GripTips.png

GRIPTIPS®, 12.5 µl Pre-sterilized, Filter

GRIPTIPS® pipette tips perfectly match the multi-lobe tip fitting, snapping firmly on during loading. This guarantees a perfect seal on every tip, preventing them from loosening, leaking or completely falling off. All tips are precisely aligned horizontally, enabling accurate touch-offs, even when pipetting with 384 tips.

Part No. 3415

See it work

Automation Friendly Reservoir, Polypropylene, Sterile, 150 ml

150 ml Clear Advantage™ reagent reservoirs are made of crystal clear 100 % virgin polystyrene for improved chemical compatibility. They fit into a reusable automation friendly base with bold, crisp, clearly visible graduation markings.

Part No. 6338

See it work

Greiner Bio-One: Tube, 15 ml, PP

  • Polypropylene displays high thermal, mechanical and chemical resistance. It is therefore recommended for the storage of chemical and biological samples
  • Diameter: 17 mm; height: 120 mm
  • Nominal volume: 15 ml
  • Working volume: 14 ml

Part No. 188271

Source: Website supplier

Visit supplier website

STARLAB: 8-Strip Non-Flex PCR Tubes, 0.2 ml

Starlab non-flex tubes have a robust, tiple link between each tube making gthem less flexible and easier to handle. The individually attached caps elinates possible cross contamination. The caps are set an angle which allows the tubes to be nested together in racks without the lids inteferring with one another.

Part No. I1402-3700

Source: Supplier Website

Visit supplier website

Eppendorf: twin.tec® PCR Plate 96

  • Semi-skirted für Beschriftung und Barcode
  • Passend für die meisten Thermocycler
  • 250 µL max. Well-Volumen (bei Verwendung mit Cap Strips)
  • Verbesserte Well-zu-Well-Toleranz
  • Mit Barcode erhältlich (auf Anfrage)
  • Ideal auch für quantitative real-time-PCR – OptiTrack®-Matrix für schnellere Probenfindung und weniger Pipettierfehler

Part No. 0030128575

Visit supplier website

Eppendorf: twin.tec® PCR Plate 384

  • Optimierter Rahmen für Barcodes und automatisierte Arbeitsabläufe
  • Stapelbar
  • Entspricht den SBS-Empfehlungen für Abmessungen
  • Ideal für die meisten gängigen 384-Well-Thermocycler, insbesondere für den Eppendorf Mastercycler X50 und den Mastercycler nexus
  • 40 µL max. Well-Volumen
  • Mit Barcode erhältlich (auf Anfrage), nur für skirted und semi-skirted
  • Ideal auch für quantitative real-time-PCR – OptiTrack®-Matrix für schnellere Probenfindung und weniger Pipettierfehler

Part No. 0030128508

Visit supplier website

Greiner Bio-One: Cellculture microplate, 96 well, PS, F-bottom

  • Improved cell adhesion through physical surface treatment
  • Free of detectable DNase, RNase, human DNA, non-pyrogenic
  • Non-Cytotoxic 
  • Compatible with automated systems

Part No. 655180

Visit supplier website

CORNING: 384 well clear flat bottom polystyrene TC-treated microplate

  • Flat bottoms with 112 µL total volume
  • Recommended working volumes of 20 to 80 µL
  • TC-treated for optimal cell attachment
  • Nonreversable lids with condensation rings to reduce contamination
  • Sterilized by gamma radiation and nonpyrogenic
  • Individual alphanumeric codes for well identification
  • Bulk packed 20 per bag

Part No. 3701

Visit supplier website

ALITHEA GENOMICS: MERCURIUS™ BRB-seq Library preparation kits for Illumina®

The MERCURIUS™ BRB-seq library preparation kits for Illumina® contain all the oligos and enzymes needed to go from purified RNA to sequencing-ready DNA libraries.

Visit supplier website

ALITHEA GENOMICS: MERCURIUS™ Cell lysate BRB-seq Library preparation kits for Illumina®

The Extraction-free Cell Lysate BRB-seq kits contain all the oligos and enzymes needed to go from 2D cell cultures and organoids to sequencing-ready DNA libraries.

Visit supplier website

Customer’s voice

Great Little Robot

"I love the ability to use it hand free, as a robot as well as being able to use it as a manual pipette. The small footprint allows us to easily move it around the lab and place it in our biological safety hoods as needed."

AMBER EDWARDS, BRT Inc