Scientist using an EVOLVE single channel manual pipette to dispense into an Eppendorf tube.

EVOLVE Manual Pipettes

Manual Pipettes

Product story

Set volumes in the blink of an eye instead of a twist of the wrist!

Traditional pipettes utilize a single rotating plunger to set the volumes. This approach makes frequent adjustment of volumes tedious, especially when switching from lower to higher volumes.

To overcome this pain point, the EVOLVE manual pipette has been designed with three adjustable dials to rapidly set volumes. This revolutionary approach reduces repetitive stress injuries and allows users to set volumes in a fraction of the time it takes with a traditional manual pipette.

How it Works

How it works

The EVOLVE manual pipette features three adjustable dials to rapidly set volumes. This approach allows users to set volumes more than ten times faster than standard manual pipettes.

  • Scientist using the EVOLVE Quick Set Dial design to change volumes on their single channel manual pipette.

    Quick Set Dials

    Unlike traditional pipettes which utilize a single rotating plunger to set volumes, EVOLVE features one dial for setting each of three volume digits. This is the same convenient method used to unlock three dial combination locks.

    Simply depress and twist the plunger to release spring tension from the volume dials.  This allows users to freely adjust all dials in either direction.  Once set, twist and return the plunger to the up position.

    Volumes set on traditional manual pipettes can often change while pipetting due to unintentional plunger turns. The EVOLVE Quick Set Dial design prevents inadvertent volume drift due to plunger movements while pipetting.

  • GripTip pipette tips snap into place with minimal tip loading effort resulting in superior accuracy and precision results.

    GripTip pipette tips which never leak or fall off

    GripTips are always firmly attached and perfectly aligned, regardless of how many side well touch offs are performed. You no longer have to hammer your pipette tips on or worry about pipette tips falling off!

    1) LOBES
    2) O-RING SEAL
    3) RIM SNAPS OVER THE LOBES
    4) SHOULDER

    The rim (3) of the GripTips will snap over the Multi-Lobes (1), attaching firmly. As a result, GripTips will never accidently fall off.

    A shoulder (4) provides a positive stop to prevent over-tightening of the tip. The GripTip can only be attached up to that point and no further, ensuring that all tips are at the same height. As a result, the tip is either on or off, but nothing in between.

  • Scientist customizing the force needed to depress the plunger of their EVOLVE manual pipette.

    Interchangeable Plunger Spring Assemblies

    Two differently sized plunger springs allow users to customize the force needed to depress the plunger to their preference. The controlled plunger spring option allows users to slow the aspiration and dispense speeds resulting in improved pipetting technique and results.

    The controlled plunger spring is compatible with all single channel EVOLVE pipettes except the 5 ml model. Changing the spring is completed in seconds.

  • A range of INTEGRA manual and electronic pipettes resting on the linear stand.

    INTEGRA Linear Stand

    Storing pipettes upright is important to prevent liquid or debris from entering the tip fitting. Proper storage also extends the life of a pipette.

    The INTEGRA linear stand is ideal for hanging EVOLVE pipettes up off the lab bench. Up to twelve manual pipettes can be placed on a linear stand. EVOLVE shelf hooks are also available for proper storage.

Customer Voices See it Work

See it work

Downloads Parts and Numbers

Parts and numbers

Single Channel EVOLVE Pipettes
Single Channel EVOLVE Pipettes

For volumes from 0.2 µl to 5000 µl

Single Channel EVOLVE Pipettes

Volume Range Part No.
0.2 – 2 µl 3011
1 – 10 µl 3012
2 – 20 µl 3013
10 – 100 µl 3015
20 – 200 µl 3016
100 – 1000 µl 3018
500 – 5000 µl 3019

Single Channel Starter Pack

3 Pipettes with Nominal Volumes Part No.
20, 200 and 1000 µl 3050
8 Channel EVOLVE Pipettes
8 Channel EVOLVE Pipettes

For volumes from 1 µl to 200 µl

Volume Range Part No.
1 – 10 µl 3022
5 – 50 µl 3024
10 – 100 µl 3025
20 – 200 µl 3026
Scientist holding an 8 channel EVOLVE manual pipette.
12 Channel EVOLVE Pipettes
12 Channel EVOLVE Pipettes

For volumes from 1 µl to 200 µl

Volume Range Part No.
1 – 10 µl 3032
5 – 50 µl 3034
10 – 100 µl 3035
20 – 200 µl 3036
16 Channel EVOLVE Pipettes
16 Channel EVOLVE Pipettes

For volumes from 1 µl to 100 µl

Volume Range Part No.
1 – 10 µl 3042
5 – 50 µl 3044
10 – 100 µl 3045
Scientist holding a 16 channel EVOLVE manual pipette.
16 Channel EVOLVE Pipette
Accessories
Accessories

Multipurpose Tool, Shelf Hooks, Plunger Caps, Spring Assembly, Linear Stand

Description Part No.
Multipurpose tool for calibration, O-ring removal and plunger spring exchange 3200
Shelf hook, 1/pack 3210
Shelf hook, 5/pack 3211
Plunger cap, black, 5/pack 3220
Plunger cap, purple (2, 10, 20 µl), 5/pack 3221
Plunger cap, yellow (50, 100 µl), 5/pack 3222
Plunger cap, green (200 µl), 5/pack 3223
Plunger cap, blue (1000 µl), 5/pack 3224
Plunger cap, orange (5000 µl), 5/pack 3225
Control spring assembly (for single channel pipettes 2, 10, 20, 100, 200 and 1000 µl only) 3230
Linear Stand, accommodates all types of INTEGRA pipettes. It can be converted to a charging stand  by attaching up to four charging stations, see electronic pipettes. 3215
Replacement O-Rings
Replacement O-Rings

Red O-rings for tip fittings

Description Part No.
200/300 µl, replacement kit, 24/pack 100-00027-50
1000/1250 µl, replacement kit, 24/pack 100-00028-50
5000 µl, replacement kit, 10/pack 100-00029-00
GripTips
GripTips

Use the GripTip Selector Guide to find your pipette tips.