VIAFLO

VIAFLO Lightweight Electronic Pipettes

Lightweight Electronic Pipettes

How To Choose Your Micropipette
Product story

The perfect pipetting system

Do your pipette tips ever loosen, leak or fall off? This is a common issue in laboratories, caused by the use of universal pipette tips. Such tips require “hammering on” which stretches the shape of the pipette tip rim. The stretched pipette tip rim immediately starts moving back to its original shape and away from the tip cone. This can cause leaking, misaligned tips and even pipette tips that completely fall off the pipette!

That is why INTEGRA designed the pipettes and GripTips in combination, resulting in a perfectly matched pipetting system. GripTips snap into place with minimal tip loading effort, providing a secure connection. GripTips never fall off and are always perfectly aligned, resulting in superior accuracy and precision results.

How it Works

How it works

Solving many issues of traditional manual pipetting, VIAFLO electronic pipettes excel in terms of ergonomics, ease of use and productivity:

  • Grip Tip System of INTEGRA pipettes

    GripTip System

    GRIPTIPS are always securely attached and perfectly aligned, regardless of how many side well touch offs are performed. You no longer have to hammer your pipette tips on or worry about pipette tips falling off!

    1) LOBES
    2) O-RING SEAL
    3) RIM SNAPS OVER THE LOBES
    4) SHOULDER

    The rim (3) of the GripTips will snap over the Multi-Lobes (1), attaching firmly. As a result, GripTips will never accidently fall off.

    A shoulder (4) provides a positive stop to prevent over-tightening of the tip. It can only be attached up to that point and no further, ensuring that all tips are at the same height. That means, the tip is either on or off, but nothing in between.

  • Menu Navigation of INTEGRA Electronic Pipettes

    Convenient operation and navigation

    The Touch Wheel is a quick and ergonomic way to modify pipetting parameters. Instead of repeatedly pushing buttons or twisting fingers to modify volumes, you simply slide your finger over the wheel.

    The full color screen provides full text menus (in multiple languages) and displays pipetting protocols without abbreviations, making VIAFLO pipettes particularly easy to understand and intuitive to use.

  • Display of INTEGRA electronic pipettes

    Various Pipetting Modes

    VIAFLO pipettes feature 10 preset pipetting programs, for which only a few parameters such as volume and speed need to be defined.

    For more elaborate pipetting protocols, up to 40 user defined custom programs can be created. The custom program is a step-based setup queuing liquid handling steps such as aspirate, dispense, mix and more.

    If connected to the VIALINK PIPETTE MANAGEMENT SOFTWARE, also complex custom programs can be quickly created and stored in a library on the computer.

    1) Currently active pipetting mode
    2) Next pipetting step is marked
    3) Aspiration volume
    4) Other parameters such as speed

Customer Voices

loading select science reviews ...

See it Work

See it work

Apps

Applications

Repeat Dispense
Repeat Dispense

Dispensing multiple aliquots of the same volume

The repeat dispense mode allows dispensing multiple aliquots of the same volume without refilling the tips after each dispense for fast microplate filling and processing.

To increase the accuracy and precision of the dispenses, a first and last dispense can be defined, which are discarded back to the source or waste.

Manual Pipet
Manual Pipet

Full control over the pipetting cycle.

The manual pipet mode gives a user full control over the pipetting cycle. Only as long as the RUN button is pressed, the pipette aspirates or dispenses. The speed and a maximal volume can be set.

This mode can be used to:

  • Measure the volume in a tube or plate
  • Perform titrations
  • Carefully aspirate supernatant without disturbing the pellet
Sample Dilute
Sample Dilute

Aspiration of two different liquids separated by an air gap.

This mode enables the aspiration of two different liquids separated by an air gap followed by a dispense of the entire tip content.

Typically this mode is used to dilute a concentrated sample by which the diluent is aspirated first, followed by the air gap and then the sample. This way the diluent chases the concentrated sample during the dispense, ensuring no residual sample remains in the tips.

Reverse Pipet
Reverse Pipet

Leaving a last dispense that is discarded.

Using this mode a larger volume is aspirated than the actual dispense, leaving a last dispense that is discarded. The function of this mode is equal to the reverse pipetting technique conducted with manual pipettes.

The reverse pipetting technique is used to pipette viscous and volatile liquids and can also improve pipetting results at very low volumes.

Variable Dispense
Variable Dispense

Dispense multiple differing volumes.

Aspirate once and dispense multiple differing volumes. Variable Dispense mode eliminates the need to adjust volumes between each dispense.

Tech Info

Tech info

Find here a quick overview of the product specifications. More detailed information can be found in the download-section below.

Battery type
Rechargeable, Li-ion, 3.7 V, 1050 mAh, Typical charging time: 2.5 hours
Mains adapter
Input: 100 – 240 V, 50/60 Hz; Output: 5.7 – 6.4 V, 3 W
Pipetting channels
1, 8, 12 or 16
Downloads Parts and Numbers

Parts and numbers

VIAFLO Electronic Pipettes
VIAFLO Electronic Pipettes

Single, 8- 12- and 16 Channel VIAFLO Pipettes

Single Channel VIAFLO II Pipettes

(Bluetooth module and power supply not included)

Volume Range Part No.
0.5 – 12.5 µl 4011
2 – 50 µl 4016
5 – 125 µl 4012
10 – 300 µl 4013
50 – 1250 µl 4014
100 – 5000 µl 4015

8 Channel VIAFLO Pipettes

(Bluetooth module and power supply not included)

Volume Range Part No.
0.5 – 12.5 µl 4621
2 – 50 µl 4626
5 – 125 µl 4622
10 – 300 µl 4623
50 – 1250 µl 4624

12 Channel VIAFLO Pipettes

(Bluetooth module and power supply not included)

Volume Range Part No.
0.5 – 12.5 µl 4631
2 – 50 µl 4636
5 – 125 µl 4632
10 – 300 µl 4633
50 – 1250 µl 4634

16 Channel VIAFLO Pipettes

(Bluetooth module and power supply not included)

Volume Range Part No.
0.5 – 12.5 µl 4641
2 – 50 µl 4646
5 – 125 µl 4642
VIAFLO single and multichannel electronic pipettes
Charging Options and Accessories
Charging Options and Accessories

Mains Adapter, Stands, Battery and Bluetooth Module

Charging Options

Type DescriptionPart No.
Mains adapter for electronic pipettes Directly charge the pipette using a mains adapter. Pipette can be used while charging.4200
Single pipette charging stand Charging stand for one pipette. Incl. mains adapter.4210
Charging/communication stand for 1 pipette In addition to charging pipettes, this stand enables the communication of a pipette with a PC and VIALINK. Incl. mains adapter.4211
Carousel charging stand for 4 pipettes The space saving carousel stand accommodates 4 electronic pipettes for charging. Incl. mains adapter.4215
Linear stand The linear stand accommodates all types of INTEGRA pipettes. It can be converted to a charging stand by attaching up to four charging stations and equipping a mains adapter (3216).3215
INTEGRA electronic pipettes charging options

Linear Stand Accessories

Type DescriptionPart No.
Mains adapter This mains adapter is required to convert the linear stand into a charging station.3216
Charging station Attach up to four charging stations to the linear stand to convert it into a charging stand. Incl. connection cable.3217
Charging/communication station In addition to charging, this station enables the communication of a pipette with a PC and VIALINK. Up to four charging/communication stations can be attached to the linear stand.3218
INTEGRA electronic pipette linear stand accessories

Battery

Type DescriptionPart No.
Pipette battery Li-ion battery4205

Bluetooth Module

Type DescriptionPart No.
Bluetooth module For VIAFLO / VOYAGER pipette4221
Replacement O-Rings
Replacement O-Rings

Red O-Rings for Tip Fittings

Description Part No.
200/300 µl, replacement kit, 24/pack 100-00027-50
1000/1250 µl, replacement kit, 24/pack 100-00028-50
5000 µl, replacement kit, 10/pack 100-00029-00
GripTips
GripTips

GripTip Pipette Tips for INTEGRA Pipettes

GripTips in Racks

Tip Size Color CodeFor PipettesDescriptionSterile FilterSterileNon-Sterile
12.5 µl LONG Purple2, 10, 12.5, 20 µl5 racks of 384440544044403
12.5 µl Purple2, 10, 12.5, 20 µl5 racks of 384 tips441544144413
125 µl Yellow50, 100, 125 µl5 racks of 384 tips442544244423
300 µl Green200, 300 µl5 racks of 96 tips443544344433
1250 µl Blue1000, 1250 µl5 racks of 96 tips444544444443
5000 µl Orange5000 µl5 racks of 96 tips445544544453
GripTip Pipette Tips in racks
GripTip pipette tips in racks

GripTips in GREENCHOICE Refills

Tip Size Color CodeFor PipettesDescriptionPre-SterilizedNon-Sterile
12.5 µl LONG Purple2, 10, 12.5, 20 µl5 inserts of 384 tips44064402
12.5 µl Purple2, 10, 12.5, 20µl5 inserts of 384 tips44164412
125 µl Yellow50, 100, 125 µl5 inserts of 384 tips44264422
300 µl Green200, 300 µl5 inserts of 96 tips44364432
1250 µl Blue1000, 1250 µl5 inserts of 96 tips44464442
GripTips pipette tips in greenchoice refills
GripTips pipette tips in GREENCHOICE refills

GripTip Bulk Packs

Tip Size Color CodeFor PipettesDescriptionSterileNon-Sterile
12.5 µl LONG Purple2, 10, 12.5, 20 µl1 bag of 1000 tips-4401
12.5 µl Purple2, 10, 12.5, 20 µl1 bag of 1000 tips-4411
125 µl Yellow50, 100, 125 µl1 bag of 1000 tips-4421
300 µl Green200, 300 µl1 bag of 1000 tips-4431
1250 µl Blue1000, 1250 µl1 bag of 500 tips-4441
5000 µl Orange5000 µl1 bag of 250 tips-4451
5000 µl Orange5000 µl1 bag of 100 tips,individually wrapped4456-
GripTip pipette tips in bulk pack
GripTip pipette tips in bulk pack
  •  

    Ask a question about VIAFLO

    Lightweight Electronic Pipettes

    Ask
  •  

    Get a quote for VIAFLO

    Lightweight Electronic Pipettes

    Quote
  •  