VIAFLO Hero Zora

VIAFLO Lightweight Electronic Pipettes

Lightweight Electronic Pipettes

Product story

The perfect pipetting system

Do your pipette tips ever loosen, leak or fall off? This is a common issue in laboratories, caused by the use of universal pipette tips. Such tips require “hammering on” which stretches the shape of the pipette tip rim. The stretched pipette tip rim immediately starts moving back to its original shape and away from the tip cone. This can cause leaking, misaligned tips and even pipette tips that completely fall off the pipette!

That is why INTEGRA designed the pipettes and GRIPTIPS® in combination, resulting in a perfectly matched pipetting system. GRIPTIPS® snap into place with minimal tip loading effort, providing a secure connection. GRIPTIPS® never fall off and are always perfectly aligned, resulting in superior accuracy and precision results.

How it Works

How it works

Solving many issues of traditional manual pipetting, VIAFLO electronic pipettes excel in terms of ergonomics, ease of use and productivity:

  • GRIPTIP® system

    GripTip pipette tips snap into place with minimal tip loading effort resulting in superior accuracy and precision results.

    GRIPTIPS® are always securely attached and perfectly aligned, regardless of how many side well touch offs are performed. You no longer have to hammer your pipette tips on or worry about pipette tips falling off!

    1) LOBES
    2) O-RING SEAL
    3) RIM SNAPS OVER THE LOBES
    4) SHOULDER

    The rim (3) of the GRIPTIPS® will snap over the Multi-Lobes (1), attaching firmly. As a result, GRIPTIPS® will never accidently fall off.

    A shoulder (4) provides a positive stop to prevent over-tightening of the tip. It can only be attached up to that point and no further, ensuring that all tips are at the same height. That means that the tip is either on or off, but nothing in between.

  • Convenient operation and navigation

    Adjusting the volume of the VOYAGER electronic pipette is easy and intuitive with the use of the touch wheel.

    The Touch Wheel is a quick and ergonomic way to modify pipetting parameters. Instead of repeatedly pushing buttons or twisting fingers to modify volumes, you simply slide your finger over the wheel.

    The full color screen provides full text menus (in multiple languages) and displays pipetting protocols without abbreviations, making VIAFLO pipettes particularly easy to understand and intuitive to use.

  • Various pipetting modes

    Color screen display of VIALFO electronic pipette with customizable pipetting program visible.

    VIAFLO pipettes feature 10 preset PIPETTING PROGRAMS, for which only a few parameters such as volume and speed need to be defined.

    For more elaborate pipetting protocols, up to 150 user defined custom programs can be created depending on the available memory capacity.

    If connected to the VIALINK PIPETTE MANAGEMENT SOFTWARE, also complex custom programs can be quickly created and stored in a library on the computer.

    1) Currently active pipetting mode
    2) Next pipetting step is marked
    3) Aspiration volume
    4) Other parameters such as speed

  • Possibilty to automate

    ASSIST PLUS Pipetting Robot

    Simply mount an INTEGRA VIAFLO electronic pipette onto the ASSIST PLUS pipetting robot, choose a pipetting protocol, add a tip rack and your labware. Press RUN and ASSIST PLUS will automatically carry out the full workflow.

  • Sustainability through longevity and plastic reduction

    Scientist taking a GREEN CHOICE refill insert with pipette tips out of the packaging

    The longer you can use a device, the better it is for the planet. At INTEGRA, we design our products to ensure low wear and easy serviceability. Moreover, we offer consumable solutions that are low in plastic, for both reservoirs and pipette tips.

    Learn more about our sustainability initiatives and goals.

Customer Voices

Customer Voices

See it Work

See it work

Apps

Uses and Applications

Overview Applications Stories

Applications

Pipet Mode
Pipet Mode

Allows liquid transfers when aspirate and dispense volumes are equal

Similar to how manual pipettes work, just with all the benefits of electronic pipettes. Watch the video to see how easy it is to use INTEGRA’s electronic pipettes for everyday use.

Repeat Dispense
Repeat Dispense

Dispensing multiple aliquots of the same volume

The repeat dispense mode allows dispensing multiple aliquots of the same volume without refilling the tips after each dispense for fast microplate filling and processing.

To increase the accuracy and precision of the dispenses, a pre- and a post-dispense can be defined, which are discarded back to the source or waste.

Sample Dilute
Sample Dilute

Aspiration of two different liquids separated by an air gap

This mode enables the aspiration of two different liquids separated by an air gap followed by a dispense of the entire tip content.

Typically, this mode is used to dilute a concentrated sample by which the diluent is aspirated first, followed by the air gap and then the sample. This way the diluent chases the concentrated sample during the dispense, ensuring no residual sample remains in the tips.

Pipet/Mix
Pipet/Mix

Transfers a defined volume and follows with a defined number of automatic mixing cycles

Mixing different liquids together in the tip in a homogenous and reproducible way.

Manual Pipet
Manual Pipet

Full control over the pipetting cycle

The manual pipet mode gives a user full control over the pipetting cycle. Only as long as the RUN button is pressed, the pipette aspirates or dispenses. The speed and a maximal volume can be set.

This mode can be used to:

  • Measure the volume in a tube or plate
  • Perform titrations
  • Carefully aspirate supernatant without disturbing the pellet
Reverse Pipet
Reverse Pipet

Leaving a last dispense that is discarded

Using this mode a larger volume is aspirated than the actual dispense, leaving a last dispense that is discarded. The function of this mode is equal to the reverse pipetting technique conducted with manual pipettes.

The reverse pipetting technique is used to pipette viscous and volatile liquids and can also improve pipetting results at very low volumes.

Variable Dispense
Variable Dispense

Dispense multiple differing volumes

Aspirate once and dispense multiple differing volumes. Variable Dispense mode eliminates the need to adjust volumes between each dispense.

Multi aspiration mode
Multi aspiration mode

Allows aspirating multiple aliquots of different volumes.

This mode can be used for a variety of collection applications where the aspiration volume is well known. This mode is also suited for supernatant collection in microplates.

Electronic pipettes are typically used to pipette into microtiter plates, but with the Multi Aspirate mode (sometimes referred to as Pooling), a known amount of liquid can aspirated back into the pipette tip from a plate.

This mode is especially useful when used in multichannel form for multiple samples at the same time, and when supernatant collection is necessary and the amount of liquid to be aspirated is a known volume.

Sample Dilute/Mix
Sample Dilute/Mix

Allows aspirating two liquids separated by an air-gap followed by a complete dispense and Mix steps.

Use this mode to perform sample dilutions where mixing of sample and diluent is required. This mode could also be used to introduce and mix diluent and sample to the first column of a serial dilution plate.

Serial dilution mode
Serial dilution mode

Allows aspirating a transfer volume followed by a mix. Rows and Mix Cycles are tracked on the display.

Use this mode to perform serial dilutions. The Serial Dilution mode enables aspiration of a specific volume followed by a mix sequence and ending with the original aspiration volume in the tips. 

Custom Programs
Custom Programs

Custom programs provide full flexibility to write and run your own protocols.

Each INTEGRA electronic micropipette allows you to create and store of up to 40 multi-step pipetting protocols, ensuring the same process is followed by every user for consistent performance and increasing reproducibility between different operators.

Steps which can be added include aspirate, dispense, mixing, timers, text prompts, and beeps.

Tech Info

Tech info

Find here a quick overview of the product specifications. More detailed information can be found in the download-section below.

Battery type
Rechargeable, Li-ion, 3.7 V, 1050 mAh, Typical charging time: 2.5 hours
Mains adapter
Input: 100 – 240 V, 50/60 Hz; Output: 5.7 – 6.4 V, 3 W
Pipetting channels
1, 8, 12 or 16
Downloads & More Parts and Numbers

Parts and numbers

VIAFLO Electronic Pipettes
VIAFLO Electronic Pipettes

Single, 8, 12, and 16 channel VIAFLO pipettes.

All VIAFLO pipettes come with:

  • Rechargeable battery (located inside the pipette)
  • 25 ml reagent reservoir SureFlo™ sample pack
  • Bag of spare O-rings (300 μl and 1250 µl volume ranges only)
  • O-ring removal tool (300 μl and 1250 μl volume ranges only)
  • Certificate of Performance

A power supply is not included. Different charging options are available to choose from. The pipette communication module is not included.

Single Channel VIAFLO Pipettes

Volume Range Part No.
0.5 – 12.5 µl 4011
2 – 50 µl 4016
5 – 125 µl 4012
10 – 300 µl 4013
50 – 1250 µl 4014
100 – 5000 µl 4015

8 Channel VIAFLO Pipettes

Volume Range Part No.
0.5 – 12.5 µl 4621
2 – 50 µl 4626
5 – 125 µl 4622
10 – 300 µl 4623
50 – 1250 µl 4624

12 Channel VIAFLO Pipettes

Volume Range Part No.
0.5 – 12.5 µl 4631
2 – 50 µl 4636
5 – 125 µl 4632
10 – 300 µl 4633
50 – 1250 µl 4634

16 Channel VIAFLO Pipettes

Volume Range Part No.
0.5 – 12.5 µl 4641
2 – 50 µl 4646
5 – 125 µl 4642
VIAFLO electronic pipette all volumes different channels
8 Channel VIAFLO Pipettes, different volumes
Charging Options and Accessories
Charging Options and Accessories

Mains Adapter, Stands, Battery, Communication Module, Wall Mount

Linear Stand Accessories

TypePart No.
Mains adapter3216
Charging station3217
Charging/communication station3218

Battery

TypeDescriptionPart No.
Pipette batteryLi-ion battery4205

Communication Module

TypeDescriptionPart No.
Pipette Communication Module For VIAFLO / VOYAGER pipette4221
Replacement O-Rings
Replacement O-Rings

O-Rings for Tip Fittings

Description Part No.
200/300 µl, replacement kit, 24/pack 100-00027-50
1000/1250 µl, replacement kit, 24/pack 100-00028-50
5000 µl, replacement kit, 10/pack 100-00029-00
GRIPTIPS®
GRIPTIPS®

Use the GripTip Selector Guide to find your pipette tips.