Setting up a 384 well qRT-PCR assay for the ViiA™ 7 using VIAFLO and VOYAGER electronic pipettes
Pipetting 64 samples in triplicate for two genes of interest (GOI), all under 10 minutes!
The qRT-PCR is set up by hand, using a VIAFLO 16 channel 125 μl electronic pipette to distribute master mixes of two genes of interest into a 384 well plate. All 64 samples are loaded directly from 1.5 ml microcentrifuge tubes into the 384 well plate in triplicate, using a VOYAGER 8 channel 12.5 μl adjustable tip spacing pipette. The whole process takes less than 10 minutes in real time!
-
Table of contents
The qRT-PCR is set up by hand, using a VIAFLO 16 channel 125 μl electronic pipette to distribute master mixes of two genes of interest into a 384 well plate. All 64 samples are loaded directly from 1.5 ml microcentrifuge tubes into the 384 well plate in triplicate, using a VOYAGER 8 channel 12.5 μl adjustable tip spacing pipette. The whole process takes less than 10 minutes in real time!
Key benefits
Set up a 384 well qRT-PCR plate by pipetting 64 samples in triplicate
The video shows how quickly and easily you can set up a 384 well qRT-PCR plate by pipetting 64 samples in triplicate for two genes of interest (GOI 1 and GOI 2).
Both master mixes are transferred from a microcentrifuge tube into a 10 ml polystyrene multichannel reagent reservoir using a single channel pipette. The GOI 1 master mix is then transferred to the left half of the 384 well plate, and the GOI 2 master mix to the right half, using the Repeat Dispense mode of the VIAFLO 16 channel 125 μl electronic pipette. Next, all 64 samples are transferred in triplicate into both the GOI 1 and GOI 2 master mixes using a VOYAGER 8 channel 12.5 μl pipette. The VOYAGER pipette’s tip spacing can be adjusted on the fly for center-to-center spacing of the tubes and the plate, enabling simultaneous direct transfer of multiple samples.
Step-by-step procedure
1. Transfer GOI 1 and GOI 2 master mixes into a 384 well plate
Add GOI 1 master mix to the left half of a 384 well plate and GOI 2 master mix to the right half (see Figure 1).
Use a VIAFLO 16 channel 125 μl electronic pipette with 125 μl Sterile, Filter GRIPTIPS®.
Select the Repeat Dispense mode and set it to dispense 12 x 7.5 μl. Depending on the viscosity of the master mix, a lower pipetting speed (e.g. speed 6) is recommended. A Pace option can be activated to minimize the need to press the pipette’s run button during dispensing, and enable automatic sequential dispensing.
2. Transferring 64 samples into a 384 well plate
Add 64 samples of GOI 1 and GOI 2 in triplicate to the master mix.
All 64 samples in microcentrifuge tubes are divided into 2 x 32 samples lined up in either a yellow or green rack and then transferred in triplicate to the GOI 1 and GOI 2 master mixes (see Figure 2), using a VOYAGER 8 channel 12.5 μl adjustable tip spacing pipette with 12.5 μl Sterile, Filter GRIPTIPS.
Choose the Repeat Dispense mode and set it to dispense 3 x 2.5 μl. A post-dispense of 1-2 μl is recommended for optimal dispensing performance. Two tip spacings are set: 13 mm (tubes in the tube rack) and 4.5 mm (center-to-center spacing of 384 well plates).
Ask our expert. Leave a comment!
Write us if you have any questions regarding the application note or one of our instruments.
Bei Fragen helfe ich Ihnen gerne weiter!
Materials
VOYAGER, 8 Channel, 12.5 µl, electronic pipette
VOYAGER pipettes allow the tip spacing to expand anywhere between 4.5 mm and 33 mm at the push of a button.
- Single handed operation leaves the other hand free to handle labware.
- On the fly access to up to 3 user-defined tip spacings.
- These user defined tip spacings are saved. No need to memorize spacings of different labware formats.
Part No. 4721
Customer’s voice
There are clear advantages of manual set-up using VIAFLO and VOYAGER pipettes. While liquid handling robots can be a good option for routine processing of large sample numbers, handheld pipettes like these give far greater control over changing sample numbers and layouts. You can pipette a 384 well plate by hand in the time it takes to set up the robot.
Related products
Applikationen
Alle anzeigen-
Automated DNA size selection for flexible NGS workflow integration
-
Automated DNA clean-up using the Zymo Research DNA Clean & Concentrator® MagBead Kit
-
Minimizing dead volume during qPCR set-up with the divided reservoir on the ASSIST PLUS pipetting robot
-
Automated qPCR master mix preparation with the D-ONE single channel pipetting module and the ASSIST PLUS pipetting robot
Stories
Alle anzeigen-
· KundenstimmenQIAGEN beschleunigt die PCR-Probenvorbereitung mit unseren flexiblen Pipettierlösungen
-
· ProduktnewsOptimieren Sie die NGS-Größenselektion und PCR-Aufreinigung mit den MAGFLO™ magnetischen Beads
-
· ProduktnewsAchieve effortless large volume PCR purification with our MAGFLO™ NGS magnetic beads and benchtop pipetting set-up
-
· ProduktnewsDie innovativen Module von INTEGRA optimieren Aufreinigungen mit magnetischen Beads