Increase your sample screening and genotyping assay throughput with the VOYAGER adjustable tip spacing pipette
Discover the advantages of setting up a genotyping assay or sample screening with the VOYAGER adjustable tip spacing pipette
Laboratories are continually facing the challenge of increasing throughput in the most efficient and economical way, to meet the need to process more and more samples per day. Traditionally, handling and manipulating samples between different labware formats involves the use of single channel pipettes, especially in screening applications and genotyping assays, which is slow, inefficient and error prone.
INTEGRA’s VOYAGER adjustable tip spacing pipette has enabled scientists from the Technical University of Munich (TUM) to benefit from the enhanced productivity of a multichannel pipette, reducing tedious liquid handling tasks.
Compared to fully automated solutions, it provides seamless liquid transfers between different standardized and non-standardized microplate, tube and gel chamber formats, and can be used without any special training. Tip spacing can be simply changed one-handedly with the push of a button, eliminating the need for any manual adjustments.
The various operating modes of the VOYAGER adjustable tip spacing pipette help to speed up monotonous pipetting steps, eliminate sample transfer errors between different labware formats, and reduce the risk of developing repetitive strain injuries.
-
Table of contents
Laboratories are continually facing the challenge of increasing throughput in the most efficient and economical way, to meet the need to process more and more samples per day. Traditionally, handling and manipulating samples between different labware formats involves the use of single channel pipettes, especially in screening applications and genotyping assays, which is slow, inefficient and error prone.
INTEGRA’s VOYAGER adjustable tip spacing pipette has enabled scientists from the Technical University of Munich (TUM) to benefit from the enhanced productivity of a multichannel pipette, reducing tedious liquid handling tasks.
Compared to fully automated solutions, it provides seamless liquid transfers between different standardized and non-standardized microplate, tube and gel chamber formats, and can be used without any special training. Tip spacing can be simply changed one-handedly with the push of a button, eliminating the need for any manual adjustments.
The various operating modes of the VOYAGER adjustable tip spacing pipette help to speed up monotonous pipetting steps, eliminate sample transfer errors between different labware formats, and reduce the risk of developing repetitive strain injuries.
Key benefits
Experimental set-up
In this protocol, two VOYAGER 8 channel adjustable tip spacing pipettes are used for a genotyping set-up. The genotyping assay is based on a PCR method with a subsequent gel electrophoresis.
The following protocol consists of sample transfers from 1.5 ml microcentrifuge tubes into a 96 well plate, and from a 96 well PCR plate into an agarose gel for electrophoresis.
Overview of the steps:
- Template transfer
- Sample transfer into the agarose gel
Step-by-step procedure
1. Template transfer
Transfer the templates into a 96 well plate.
Use a VOYAGER 8 channel 300 μl electronic pipette with 300 μl Sterile, Filter GRIPTIPS®. Select ‘Tip spacing’ in the main menu of the pipette to set the required spacing. Choose ‘Positions: 2’ in the tip spacing menu and set the tip spacing according to the 96 well plate and the microcentrifuge tubes in the rack (Figure 1). Once saved, the tip spacing is available at any time, for any other pipetting modes.
After saving the tip spacing, select ‘Pipet’ mode in the main menu. Set your required sample transfer volume and pipette the templates from the 1.5 ml microcentrifuge tubes into the 96 well plate (Figure 2). By pressing left and right on the Touch Wheel interface, the tip spacing can be adjusted on the fly to fit each labware format.
Tips:
- Use the Repeat Dispense mode to dispense several samples successively if duplicate or triplicate samples are required.
- Use the Pipet/Mix mode if samples require mixing in the target wells. Settings like mixing cycles, pipetting speeds and volumes can quickly be adjusted.
2. Sample transfer into the agarose gel
Transfer the PCR product into the agarose gel.
After PCR, use the VOYAGER 8 channel 125 μl electronic pipette with 125 μl Sterile, Filter GRIPTIPS to transfer the samples from the 96 well PCR plate into the agarose gel for subsequent gel electrophoresis (Figure 3). As in step 1, choose ‘Positions: 2’ in the tip spacing menu and set the tip spacing according to the 96 well PCR plate and the agarose gel.
Set the required sample volume as described in step 1 and transfer the samples from the PCR plate into the agarose gel.
Tips:
- A low dispensing speed (e.g. 4) helps uniform filling of the wells in the agarose gel.
- If you want a controlled blowin – rather than automatic – keep the run button pressed while dispensing. Blowin will occur when the run button is released.
Conclusion
Related articles
Ask our expert. Leave a comment!
Write us if you have any questions regarding the application note or one of our instruments.
Any questions? I'm happy to help!
Instruments and accessories
VOYAGER, 8 Channel, 125 µl, electronic pipette
VOYAGER pipettes allow the tip spacing to expand anywhere between 4.5 mm and 33 mm at the push of a button.
- Single handed operation leaves the other hand free to handle labware.
- On the fly access to up to 3 user-defined tip spacings.
- These user defined tip spacings are saved. No need to memorize spacings of different labware formats.
Part No. 4722
Download
Download App Note as PDF
DownloadIncrease your sample screening and genotyping assay throughput with the VOYAGER adjustable tip spacing pipette
Customer’s voice
The Voyager Series of Electronic pipettes is one of the easiest and convenient pipettes I have ever used. The ergonomic stability of these pipettes adds to the already excellent accuracy and precision. The programmable spacing of the tip heads makes it a breeze to transfer samples from PCR/source plates to Dilution plates to ELISA or other types of assay plates. These pipettes have quickly become the lab favorite.
Related products
Applications
Show all-
Accelerated loading of Fluidigm's 192.24 Dynamic Array™ IFC for genotyping with the ASSIST PLUS pipetting robot
-
Automated DNA extraction protocol to effortlessly isolate gDNA from blood
-
Automating the Corning Matrigel® thin coating protocol for cell culture applications
-
Automation-enabled high throughput electroporation of primary cells using the ASSIST PLUS and DropGenie platform
Stories
Show all-
· Customer TestimonialCultivating a successful future with VOYAGER adjustable tip spacing pipettes
-
· Customer TestimonialSowing the seeds of the future with VIAFLO 96 and VIAFLO 384 pipettes
-
· Customer TestimonialExploring targeted treatments for chronic pain using VOYAGER pipettes
-
· Customer TestimonialEnhancing the consistency of ag-tech R&D processes with the ASSIST PLUS pipetting robot
-
· Customer TestimonialQIAGEN is accelerating PCR sample prep with our flexible pipetting solutions
-
· Product NewsErgonomic pipettes and pipetting guidelines