Product story

Endless applications on the ASSIST PLUS – automated normalization, hit picking and master mix prep in a snap

The D-ONE single channel pipetting module offers hands-free transfers from individual tubes or wells on the ASSIST PLUS pipetting robot. This makes it the perfect add-on for labs that want to go beyond the possibilities of multichannel pipetting to access unlimited applications. It is designed to offer easy automation of normalization, hit picking and master mix preparation, freeing up your time while eliminating transcription errors.

How it Works

The ASSIST PLUS with the D-ONE single channel pipetting module offers automated, hands-off and worry-free processing.

D-ONE Overview
  1. The D-ONE single channel pipetting module is available in two volume ranges: 0.5 to 300 µl and 5 to 1250 µl.
  2. Pipetting with a single channel offers maximum flexibility, with automatic liquid level detection.
  3. A special D-ONE tip deck can accommodate two tip racks, allow the ASSIST PLUS to switch between 12.5/300 µl or 125/1250 µl GRIPTIPS® without manual intervention.

Customer Voices See it Work

See it work

Apps

Uses and Applications

Normalization

Calculates the correct volumes of diluent for each sample

Normalizing or equalizing sample concentrations involves dilution calculations based on varying volumes of diluent and sample for each well. Using the D-ONE single channel pipetting module on the ASSIST PLUS allows hands-off, worry-free processing of this error-prone task. Only the initial and target concentrations need to be entered in the VIALAB software, which calculates the correct volumes of diluent for each sample. Broad volume ranges, from 0.5 to 300 µl or 5 to 1250 µl, ensure very high or low concentration samples can be processed without manual tool changes.

Normalization with D-ONE
Normalizing or equalizing sample concentrations with D-ONE
Hit or cherry picking

Sample transfers from single wells to the target plate

During hit or cherry picking, individual samples from several source plates are transferred to a single target plate for further analysis. Using the D-ONE single channel pipetting module on the ASSIST PLUS, sample transfers from single wells to the target plate are possible. Importing worklists to VIALAB makes programming effortless and minimizes set-up time.

Hit picking with D-ONE for ASSIST PLUS
Hit picking with D-ONE
Master mix preparation

Mixing individual components

The combination of several reagents – reaction buffer, primers and enzymes – at different volumes is the first step for preparing all PCR reactions. Using the D-ONE single channel pipetting module on the ASSIST PLUS, mixing the individual components can be easily automated. The number of reactions can be easily changed, and the total volumes are automatically adjusted in VIALAB. Broad volume ranges, from 0.5 to 300 µl or 5 to 1250 µl, ensure very high or low concentration samples can be processed without manual tool changes.

PCR Master Mix preparation with D-ONE
PCR Master Mix preparation with D-ONE
Next generation sequencing

Use the D-ONE single channel pipetting module in your NGS workflow.

Quality control for NGS library preparation can be tedious and error prone if performed manually. Using the D-ONE single channel pipetting module on the ASSIST PLUS pipetting robot enables automated, worry-free normalization and pooling of your NGS libraries before sequencing. With broad volume ranges from 0.5 to 300 µl or 5 to 1250 µl, the D-ONE is well suited to the various concentrations used during library preparation. This all-in-one pipetting option avoids manual tool changes and minimizes human errors in the final steps of your NGS library preparation workflow.

Find out about all the potential applications of the D-ONE in NGS workflows here.

INTEGRA products used in an NGS workflow.
Standard curve preparation

Precise serial dilutions

Precise serial dilutions are needed to prepare standard curves for quantitative assays, such as ELISAs or qPCRs. Standards are typically provided in individual tubes, and need to be serially diluted to cover the full dynamic assay range. With the D-ONE pipetting module, precise serial dilutions can be performed in tubes or directly in the assay plate. The correct tip is automatically chosen according to the diluent or sample volume, ensuring high precision pipetting results.

Samples with different filling level

Detection of the liquid level

The D-ONE single channel pipetting module allows automatic detection of the liquid level, making it the ideal tool for pipetting varying liquid volumes into sample tubes. The sample is aspirated at the optimal height, where the tip is only just submerged in the liquid, to ensure high precision pipetting results. This eliminates tedious manual adjustment of liquid levels for faster program set-up.

Detection of sample level in tubes or other labware
Automatic detection of the liquid level
Tech Info

Tech info

Find here a quick overview of the product specifications. More detailed information can be found in the download-section below.

Compatible with

ASSIST PLUS

Number of channels:

1

Pipetting technology

Air displacement

Volume range

0.5-300 µl / 5-1250 µl

Battery

Rechargeable, Li-ion, 3.7 V, 1050 mAh; Typical charging time: 2.5 hours

Mains adapter

Input: 100-240 V, 50/60 Hz; Output: 5.7-6.4 V, 3 W

Downloads & More Parts and Numbers

Parts and numbers

Instrument

D-ONE Pipetting Module

Description Part no.
D-ONE Single Channel Pipetting Module, 0.5-300 µl 4531
D-ONE Single Channel Pipetting Module, 5-1250 µl 4532
D-ONE All in one bundle
D-ONE 0.5 – 300 µl and D-ONE 5 – 1250 µl,
Tip Deck, Labware Pedestal, 2 x Communication Module
4539
D-ONE Single Channel Pipetting Module, 0.5-300 µl and 5-1250 µl
D-ONE Single Channel Pipetting Modules, 0.5-300 µl and 5-1250 µl
Accessories

Tip deck and communication options for D-ONE

DescriptionPart no.
Tip deck for D-ONE on ASSIST PLUS
(Compatible with 0.5-300 µl and 5-1250 µl D-ONE modules)
4535
Portrait labware pedestal4551
Pipette Communication Module for D-ONE4222
Charging/communication stand for 1 pipette, incl. mains adapter4211

For more labware accessories, visit the ASSIST PLUS product page

GRIPTIP® pipette tips

Use the GripTip Selector Guide to find the correct pipette tips

D-ONE Single Channel Pipetting Module, 0.5-300 µl

Compatible with 12.5 and 300 µl GRIPTIPS® for benchtop pipetting systems

D-ONE Single Channel Pipetting Module, 5-1250 µl

Compatible with 125 and 1250 µl GRIPTIPS® for benchtop pipetting systems